Á¦Ç°    

오실로스코프
프로토콜 분석기
차동증폭기
프로브
Current Probes
Active Probes
Passive Probes
Differential Probes
High-Voltage Probes
Transmission Line Probes
OE Converters
Probe Accessories
오토모티브/차량 테스트
혼합 시그널 테스트 솔루션
모듈 기기
스코프 액세서리
하드웨어 옵션
소프트웨어 옵션
단종 제품

      

Model DXC100A

dxc100.gif (28254 bytes)

Main Features

  • DC to 100 MHz Bandwidth with DA1855A
    DC to 10 MHz Bandwidth with DA1822

  • Max Input Voltage 500 V

  • Selectable 10 or 100 Attenuation Factor

  • 1.2 Meter Cable Length

The DXC100A is a high-performance, passive, matched, differential probe pair designed for use with the DA1800 series differential amplifiers. The probe pair consists of two highly matched individual probes that share a common compensation box to allow the attenuation factor on both probes to be simultaneously switched between 10x and 100x. When used with the DA1822 or DA1855A differential amplifier, the probe's attenuation factor is automatically incorporated into the effective gain display, and the location of the decimal into the voltage generator display. Although primarily designed for use with the amplifiers, the DXC100A differential probe pair can be used with any oscilloscope or plug-in unit with an input impedance of 1 M(omh)/15-26 pF and one inch (25.4 mm) spacing between connectors. When used on a differential amplifier, the DXC100A compensation box allows for precise adjustment and matching of the transient response and optimization of the system Common Mode Rejection Ratio (CMRR).

Specifications
 
General
Attenuation factor 10 or 100
Bandwidth (-3 dB) 250 MHz
System Bandwidth: (-3 dB) (with DA1855): 100 MHz
(with DA1822): 10 MHz
System Risetime  (with DA1855): 3.5 ns
(with DA1822): 35 ns
Input Resistance 1 M(ohm) ±1%
Input Capacitance 10.5 pF ±0.5 pF
Compensation Range:  15 to 26 pF
Maximum non-destructive Input Voltage 500 V DC + peak AC
Length 1.2 meter
 
 
Environmental Characteristics
Operating Range 0° to 50°C
Non-Operating -4° to 75°*C
 

 
Physical Characteristics
Weight 0.21 kg (0.47 lb)
Shipping Weight 0.45 kg (1 lb)
Warranty 1 year
   
 
Model Description
  DXC100A 100:1 or 10:1 Selectable 250 MHz Passive Differential Probe Pair
  DXC200 1:1, 50 MHz Passive Differential Probe Pair
DXC5100 100:1, 250 MHz, 2.5kV High Voltage Probe Pair
DA101 10:1, 1 MOhm Passive Attenuator
DA18XX-RM01 Rackmount Adapter for DA18XX-PR2, Size (2U)
 
To view a list of DISCONTINUED PRODUCTS click this link.
(¿ì)135-280 ¼­¿ï °­³²±¸ ´ëÄ¡µ¿ 968-5 Àϵ¿ºôµù 10Ãþ TEL.02-3452-0400 FAX.02-3452-0490
Copyright © LeCroy Corporation 2009