PRODUCTS    

Oscilloscopes
Protocol Analyzers
Differential Amplifiers
Probes
Automotive/Vehicle Test
Mixed Signal Test Solutions
Modular Instruments
Scope Accessories
Hardware Options
Software Options
Discontinued Products
    
    
PXD222 (Discontinued)

Leading Features

  • 200 MHz bandwidth

  • 2.5 GS/s single shot sample rate

  • Up to 1000 points in Normal Scope Mode

  • Up to 27,500 points per record in MIN - MAX capture modes

  • Independent floating isolated inputs (300V CAT II safety certified)

  • Capture glitches as fast as 50ns in time-windows from 50us to 50s

  • Advanced trigger modes including automatic, edge, video glitch and pulse width

  • Supports PXI_TRIG and PXI_STAR triggers

  • 3U PXI 2 slot form factor

  • IVI scope drivers and quick start software

  • CompactPCI compliant

    File in PDF format


The LeCroy PXD222 provides a high performance digitizer solution for manufacturing test, defense, and research applications.

The PXD222 digitizer features 200 MHz and 2.5 GS/s single shot sampling in a 2 slot 3U PXI form factor. It also features advanced triggering and 300 V CAT II safety-certified isolated inputs for demanding applications. In addition to the Normal acquisition mode where up to 1000 points are captured at up to 2.5 GS/s, the module includes a Glitch Capture and Scope Record modes. The Glitch Capture Mode allows captures of glitches as fast as 50ns in time windows from 50us to 10s. In Scope Record Mode, the PXD222 stores 27Kpts while sampling the data at up to 20MS/s.  Both of these modes oversample the waveform and returns the MIN and MAX values found in each time interval. The combination of these features allows for the capture of complex signals with excellent accuracy within the compact, sturdy, modular architecture of PXI.

The PXD222 digitizer is fully PXI compliant and is based on the desktop computer industry standard PCI bus. The plug and play functionality of the PXD222 digitizer provides ease of set-up and use.

The PXD222 digitizer includes several software tools to help you quickly get started and develop test software in LabVIEW, CVI, Visual C++ or Visual Basic. 

The PXD series software includes an IVI-Scope Instrument driver and a quick start application program for interactive control.

The LeCroy PXD222 digitizer provides a cost efficient, space efficient, high performance solution for production test applications including:

• High Energy Physics
• Radar and Lidar
• Disk Drive Testing
• Communications Test Systems
• Automotive
• Aerospace and Defense

Technical Specifications 

Vertical  
Bandwidth, DC Coupled:  200 MHz (-3 dB)
Bandwidth Limiters:  20 MHz and 10 kHz
Input Coupling:  AC, DC
Full Scale Ranges: direct (4-8-16 sequence) beginning at 40 mV
Positioning: Offset adjustable to 100% of full range
Input Impedance on BNC: DC Coupled 1 MOhms (±1 %)//15 pF (±2 pF)
Max. Input Voltage:  direct (1:1) 300 V CAT II
with 10:1 probe 1000V
Vertical Accuracy:  ±2% of full range
Digitizer Resolution:  8 bits
 
HORIZONTAL
General  
Maximum Sample Rate
Single Shot:  2.5 GS/s
Digitizers:  2
Time Base Accuracy:  ±100 ppm
Acquisition Modes: 
  
Single Sweep
Normal Acquisition Mode  
Record Size:  up to 1000 samples/ch
Recorded Time Span: 
 
100ns to 10s
Glitch Capture Mode  
Record Size:  250 points (Min and Max data arrays returned)
Recorded Time Span:  50us to 10s detect glitches as fast as 50ns by oversampling waveform
Sample Rate:
 
up to 2.5 GS/s
Scope Record Mode  
Record Size:  27K points (Min and Max data arrays returned)
Recorded Time Span:  11 s to 36 hours
Sample Rate:  up to 20 MS/s
 
Trigger and Delay  
Trigger Modes:  Automatic, Normal, Single Shot
Trigger Delay:  up to 100 times the recorded time span
Pre Trigger View:  90% of the recorded time span
Max. Delay:  10 seconds
 
Edge Trigger  
Source: Ch1,Ch2,PXI_TRIG[n],PXI_STAR[n]
Slope:  Positive, Negative
Trigger Level Control Range:  100% of full range
 
Video Trigger  
Standards:  PAL, PAL+, NTSC, SECAM
Modes:  Lines, Line Select, Field 1 or Field 2
Source:  Ch2
Polarity:  Positive, Negative
Pulse Width Trigger  
Trigger Conditions:  <T, >T — min 450ns =T (±10 %), ¤T(±10 %) resolution of 50ns
Source:  Ch2
Polarity:  Positive or negative pulse
Glitch Trigger:
  
Trigger Conditions. <T, - min 300ns
Parameter Measurements  
VDC, VAC rms, VAC+DC, Vpeak max, Vpeak min, Vpeak to peak, Frequency,Positive Pulse Width, Negative Pulse Width, Positive Duty Cycle, Negative Duty Cycle, Phase
 
Mechanical  
Size:  3U height x 2 slots 
Weight:  1.7 lbs.
 
Power requirements +5 VDC 1.6 A
 
Environment and Safety
Temperature:  
Operating  0°C to 50°C (32°F to 122°F) with specified cooling of PXI-rack
Non-operating  -40°C to +71°C. 
 
Humidity:   
Operating  5% to 95% max RH (non-condensing) up to +30°C, Upper limit derates to 45% RH (non-condensing) at 50 degrees C. 
Non-operating  5% to 95% RH (non-condensing) up to 30°C; Upper limit derates to 45% RH (non-condensing) 
at 60°C 
Altitude:  
Operating  15,092 ft. (4,600 m). 
Non-operating  39,377 ft. (12,000 m).
 
Shock & Vibration:  
Conforms to MIL-PRF-28800 Class 3
Electromagnetic Compatibility:  
Emissions and Immunity EN 61326-1:1997 +A1:1998 
Safety:  
Safety specifications are only valid if the unit is properly installed.
Designed for measurements on 300V Category II Installations per:
EN 61010-1:1994
CAN/CSA-C22.2 No.1010.1-92
UL3111-1
 
Approvals:  
CE Approved
UL and cUL approved
 
Warranty:  1 Year

Ordering Information Product Code
PXI Digitizer 200 MHz, 2.5GS/s  PXD222

Copyright © LeCroy Corporation 2009